Workstations PAMIR-RM and engineering stations PAMIR-IS are
intended for fulfillment of main information tasks:
- execution of calculations
- data exchange
- information storage
- terminal functions (keyboard, manipulator, display)
Are implemented in alternatives:
- one-cabinet construction (PAMIR-RM)
- cabinet with remote display and keyboard (PAMIR-IS)
| FUNCTIONALITY |
| |
|
| Processor
unit |
1-2 processors
of Intel of Pentium, Ultrasparc - 32-64-digits, 500-733
MHz, RAM - up to 1 GB on processor unit |
| |
|
| HDD |
1 disk drive
36 Gb |
| |
|
| Interfaces |
Centronics,
RS-232, RS-485, Ultra-Wide SCSI-2, USB, Ethernet - up to
24 ports 10/100/1000 TX/FX UTP/FO |
| |
|
| Display |
resolution up
to 1280õ1024, 16 million colors at monitor refresh
frequency not less than 60 Hz |
| |
|
| System
software |
on base of
Solaris 8, Red Hat Linux 7.3 |
| |
|
| Standards,
protocols, services, packets |
POSIX,
X-Window, C ANSI, TCP/IP, FTP, NFS, TELNET, Motif |
| |
|
| Auto-start |
self-acting
start of applied software at ltirn-on or reboot |
| |
|
| Monitoring |
- diagnostics
and control of components via SNMP protocol |
| |
- supervision
and exception handling of applied software |
| |
|
| Test
software |
- write / read
on HDD
- data exchange via Ethernet
- displaying graphic and text information on the monitor
- usage of operational resources and processor load
- output of graphic and test information to printer
- operation in real time, response to interruptions from
the keyboard and manipulator, priorities of task
execution
- execution of applied software |
| |
|
 |
| RELIABILITY |
| |
|
| Reliability
of components |
self-diagnostics,
equipments of the remote monitoring and reconfiguring |
| |
|
| Average
mean-time-between failures |
not less than
12000 h |
| |
|
| Mean time
of restoring |
no more than 1
h |
| |
|
| Availability |
not less than
0,99995 for various implementations |
| |
|
| Average
service life |
not less than 10
years on condition of changeover of separate modules and
units which have worked out the operational life |
| |
|
 |
|
| PROTECTION
AGAINST EXTERNAL INFLUENCES |
| |
|
| Vibro-
& shock stability |
- at sine-wave
vibrations by intensity 0.12 g (1.2 m/s²)
over the range 1-100 Hz in powered state, 0.25 g (2.5 m/s²)
over the range 1-100 Hz in switched-off state
- single impact with maximal amplitude of peak
shock acceleration up to 3 g (30 m/s²)
with duration 10 ms (Ì38 according to GOST 17516) |
| |
|
| Seismic
stability |
operability at
earthquake with intensity 0.5 g (5 m/s²)
over the range 1-35 Hz |
| |
|
| Electromagnetic
compatibility and noise-immunity |
- group of implementation
III for electromagnetic environment of middle rigidity
with operation performance criterion "A" at
effect of interferences according to GOST R50746 (including
IEC 1000-4-2, 3, 4, 5, 8, 9, 11)
- emission of man-made interferences - class
"A" according to GOST 29216, GOST R50033
|
| |
|
| Interruption
of external power supply |
up to 20 min,
automatic stop and restart |
| |
|
| Atmospheric
conditions |
- working
values:
air temperature of from +10 up to +40 °Ñ,
air relative humidity of 80 % at 25 °Ñ
- limiting values:
air temperature from +1 up to +45 °Ñ,
air relative humidity of 98 % at 35 °Ñ |
| |
|
| Access to
dangerous parts, hit of external hard subjects, waters |
IP21 |
| |
|
 |
| SAFETY |
| |
|
| Fire safety |
according to
GOST 12.1.004, probability of fire origination in
products less than 0.000001 per one year |
| |
|
| Protection
against electric-shock hazard |
01 class
according to GOST 12.2.007.0 |
| |
|
| Protection
against unauthorized access |
physical
protection, control of access to hardware and
software components |
| |
|
 |
| TRANSPORTATION
AND STORAGE |
| |
|
| Transportation |
on any
distances by automobile and railway transport (in
obturated transport facilities), water
carriage (in holds of ships) or aviation (in pressurized
bays) |
| |
|
| Requirements |
air
temperature from -20 °C; up to + 50 °C, in other
respects - demands to storage 3 (Zh3) or 6 (Zh2)
according to GOST 15150 |
| |
|
 |
| SERVICE
CONDITIONS |
| |
|
| Power
supply |
220 (+10 %,
-15 %) V
50 (+2 %, -3 %) Hz |
| |
|
| Power
consumption |
no more than
600 V·A |
| |
|
 |
| OVERALL
DIMENSIONS AND MASS |
|
| |
|
| Width õ
depth õ height õ mass (no more) |
600 x 700 x
850 (with the monitor on the rack - 1200) x 150 kg |
| |
|
 |
|
* Remarks: these data can vary for
different implementations. Exact information - in the technical
documentation of the company.
| |
|
|

RM-01R-08 |

RM-01R-09 |
 

IS-01P-03 |
|