Base computer equipment PAMIR-BS are intended for fulfillment of
main information tasks:
- data communication
- execution of calculations
- information storage
and constructing on their basis of instrumentation and control
systems. The place for installation of measuring and control units
with cable wiring inside cabinets and organization of cable entries
are provided.
| FUNCTIONALITY |
| |
|
| Processor
unit |
Intel Pentium
500 MHz, RAM 128 MB |
| |
|
| HDD |
1 disk drive 9
GB / RAID 1 level (2 disk drives) 9 GB |
| |
|
| Interfaces |
Centronics,
RS-232, RS-485, Ultra-Wide SCSI-2, USB, Ethernet - up to
24 ports 10/100/1000 TX/FX UTP/FO |
| |
|
| Terminal
unit |
resolution up
to 1280õ1024, 16 million colors at monitor refresh
frequency not less than 60 Hz |
| |
|
| System
software |
on base of Red
Hat Linux 7.3 |
| |
|
| Standards,
protocols, services, packets |
POSIX,
X-Window, C ANSI, TCP/IP, FTP, NFS, TELNET, Motif |
| |
|
| Auto-start |
self-acting
start of applied software at turn-on or reboot |
| |
|
| Monitoring |
- diagnostic
and control of components via SNMP protocol |
| |
- supervision
and exception handling of applied software |
| |
|
| Test
software |
- write / read
on HDD
- data exchange via Ethernet
- displaying graphic and text information on
monitor
- usage of operational resources and processor load
- output of graphic and test data to printer
- operation in real time, responses to interruptions
from the keyboard and manipulator, priorities of task
execution
- execution of applied software |
| |
|
 |
| RELIABILITY |
| |
|
| Reliability
of builders |
self-diagnostics,
equipments of the remote supervision and reconfiguring |
| |
|
| Average
mean-time-between failures |
not less than
20000-45000 h for various implementations |
| |
|
| Mean time
of restoring |
no more than 2
h |
| |
|
| Availability |
not less than
0,99995-0,99998 for various implementations |
| |
|
| Average
service life |
not less than 10
years under condition of changeover of separate modules
or units which have worked out the operational life |
| |
|
 |
|
| PROTECTION
AGAINST EXTERNAL ACTIONS |
| |
|
| Vibro-
& shock stability |
- at sine-wave
vibrations with intensity 0.12 g (1.2 m/s²) over
the range 1-100 Hz in powered state, 0.25 g (2.5 m/s²)
over the range 1-100 Hz in switched-off state
- single impact with maximal amplitude of peak shock
acceleration up to 3 g (30 m/s²) with
duration 10 ms (Ì38 according to GOST 17516) |
| |
|
| Seismic
stability |
operability at
earthquakes with intensity 0.5 g (5 m/s²) over the
range 1-35 Hz |
| |
|
| Electromagnetic
compatibility and noise-immunity |
- group of implementation
III for electromagnetic environment of middle rigidity
with operation performance
criterion "A" at
effect of interferences in accordance with GOST R50746
(including IEC 1000-4-2, 3, 4, 5, 8, 9, 11)
- emission of man-made interferences - class
"A" according to GOST 29216, GOST R50033
|
| |
|
| Interruption
of external power supply |
up to 20 min
(taking into account complexed equipment - up to 8
min), automatic stop and restart |
| |
|
| Atmospheric
conditions |
- working
values:
air temperature from +10 up to +40 °Ñ,
air relative humidity of 80 % at 25°Ñ
- limiting values:
air temperature from +1 up to +45 °Ñ,
air relative humidity of 98 % at 35 °Ñ |
| |
|
| Access to
dangerous parts, hit of external hard subjects, waters |
IP20/IP30 |
| |
|
 |
| SAFETY |
| |
|
| Fire safety |
according to
GOST 12.1.004, probability of fire origination in
products less than 0.000001 per one year |
| |
|
| Protection
against electric-shock hazard |
01 class
according to GOST 12.2.007.0 |
| |
|
| Protection
against unauthorized access |
physical
protection, control of access to hardware and software
components |
| |
|
 |
| TRANSPORTATION
AND STORAGE |
| |
|
| Transportation |
on any
distances automobile and a railway transport (in
obturated transport facilities), water-carriage (in
holds of ships) or aviation (in pressurized bays) |
| |
|
| Requirements |
air
temperature from -20°Ñ up to + 50°Ñ, in other
respects - demands to storage 3 (OZh3) or 6 (OZh2)
according to GOST 15150 |
| |
|
 |
| SERVICE
CONDITIONS |
| |
|
| Power
supply |
220 (+10 %,
-15 %) V
50 (+2 %, -3 %) Hz |
| |
|
| Power
consumption |
no more than
1000 V·A (taking into account
complexed equipment) |
| |
|
 |
| OVERALL
DIMENSIONS AND MASS |
|
| |
|
| Width õ
depth õ height õ mass (no more) |
600 x 880 x
1800 mm x 200 kg (taking
into account complexed equipment - up to 265
kg) |
| |
|
 |
|
* Remarks: these data can vary for
different implementations. Exact information - in the technical
documentation of the company.
| |
|
|

BS-01R-01 |

BS-01R-03 |

BS-01R-04 |
| |
|
|
|